Engineering Design NIDisk Guía de usuario

Busca en linea o descarga Guía de usuario para Máquina de reducción de ruido Engineering Design NIDisk. Engineering Design NIDisk User guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - User Guide

NIDisktm Direct-to-disk Recorder User Guide Version 3.03 February, 2007 Revised April, 2007 Engineering Design

Pagina 2

NIDisk User Guide 4 NIDisk User Guide The NIDisk User Guide (this document) is installed as a PDF (Portable Document Format) file in the \docs directo

Pagina 3 - LICENSE AGREEMENT

NIDisk User Guide 5 4. Acquisition Performing Acquisition To perform an acquisition, select I/O | Acquire on the NIDisk menu. NIDisk displays the Acq

Pagina 4

NIDisk User Guide 6 Sample rate may be selected from the drop list of available sample rates in Hz or entered manually. Available sample rates vary w

Pagina 5 - Table of Contents

NIDisk User Guide 7 Triggering allows the user to initiate acquisition manually by clicking OK [Manual] or by applying an external TTL signal [Externa

Pagina 6

NIDisk User Guide 8 5. Playback Performing Playback To perform a playback, select I/O | Play on the NIDisk menu. NIDisk displays the Playback paramet

Pagina 7 - 1. Overview

NIDisk User Guide 9 • SIGNAL files are played at their original voltage range, using a conversion factor stored in the SIGNAL file header. • Wave fi

Pagina 8 - 2. Installation

NIDisk User Guide 10 6. Simultaneous Acquisition/Playback About Simultaneous Acquisition/Playback NIDisk can perform simultaneous acquisition and play

Pagina 9 - Enable SIGNAL Security Key

NIDisk User Guide 11 Acquisition/Playback Parameter Screen The Acquisition/Playback parameter screen allows the user to specify acquisition duration,

Pagina 10 - 3. Getting Started

NIDisk User Guide 12 Acquisition/Playback Summary Screen After closing the acquisition/playback parameter screen, NIDisk displays a summary of the ac

Pagina 11 - 4. Acquisition

NIDisk User Guide 13 During simultaneous acquisition/playback, only the acquisition progress screen is displayed. Elapsed Time Display The meter shows

Pagina 12 - NIDisk User Guide

This document is provided for the sole purpose of operating the NIDisk system. No part of this document may be reproduced, transmitted, or stored b

Pagina 13 - Acquisition Summary Screen

NIDisk User Guide 14 Here is the meter after recording with low headroom represented by a yellow bar: and here is the meter during an overload condi

Pagina 14 - 5. Playback

NIDisk User Guide 15 the display. The total headroom value is reflected in both the numerical readout and bar display. 8. Acquisition and Playback Tr

Pagina 15 - Playback Summary Screen

NIDisk User Guide 16 4. Acquisition or playback will begin on receipt of the external trigger signal. Triggering an External System from NIDisk Outpu

Pagina 16

NIDisk User Guide 17 9. Other Functions Alarm Sounds NIDisk can produce alarm sounds to alert the user to certain acquisition or playback conditions.

Pagina 17

NIDisk User Guide 18 (to avoid specifying parameters on the setup screen) and for automation and interfacing with SIGNAL, as described below. Command

Pagina 18

NIDisk User Guide 19 will acquire two channels for 60 seconds at 50 kHz sample rate per channel with a gain multiplier of 10, to a two-channel SIGNAL-

Pagina 19 - Headroom Display

NIDisk User Guide 20 RA family commands) to determine when the I/O process has completed and whether it was successful. 11. Operating Hints and Troubl

Pagina 20 - Final Meter Display

NIDisk User Guide 21 1. If the I/O device is not present or is not named "Dev1", NIDisk issues the following message: If the device is not

Pagina 21

NIDisk User Guide 22 4. If NIDisk has (or may have) terminated abnormally, it may be running as a "phantom" process and preventing other NI

Pagina 22 - IO_ACTIVE connection

NIDisk User Guide 23 Disk Fragmentation and Maximum Sample Rate On older hard disks, fragmentation can degrade the maximum sample rate. Disks can

Pagina 23 - 10. Command Line Mode

LICENSE AGREEMENT THIS IS A LEGAL AGREEMENT BETWEEN ENGINEERING DESIGN AND THE BUYER. BY OPERATING THIS SOFTWARE, THE BUYER ACCEPTS THE TERMS OF T

Pagina 24 - Command Line Syntax

NIDisk User Guide 24 select the Power Save Mode tab, and move the 4 slider controls associated with Processor Speed to Full, 4) click OK. Running the

Pagina 25 - Status File

NIDisk User Guide 25 Minimum sample rate 100 Hz Maximum sample rate 500 kHz Programmable gain 1, 2, 5, 10, 20, 50, 100 Impedance 100 G-o

Pagina 26

NIDisk User Guide 26 the input signal is V(t) = A sin 2πft, then voltage change is dV/dt = 2πfA cos 2πft, whose maximum = 2πfA Volts/sec. So instanta

Pagina 27

NIDisk User Guide 27 • SIGNAL can display the entire sound file (see below), which the researcher can use as a roadmap to extract specific sound even

Pagina 28 - I/O Errors

NIDisk User Guide 28 spectrogram with typically 30-60 seconds of sound per screen. This allows the user to navigate through a long recording, spottin

Pagina 29 - Notebook Power Management

NIDisk User Guide 29 The wide screen and high-resolution spectrogram of the RTS can be used to locate events in sparse data sets. For example, the

Pagina 30 - 12. Technical Notes

NIDisk User Guide 30 The RTS runs within SIGNAL, so sound segments can be transferred easily to SIGNAL buffers for immediate analysis, and measured so

Pagina 32 - 13. Using NIDisk and SIGNAL

Table of Contents 1. Overview... 1 2. Installation...

Pagina 34 - 14. Using NIDisk with RTS

1. Overview NIDisktm provides direct-to-disk data acquisition and playback using analog I/O cards from National Instruments. Program capabilities in

Pagina 35

NIDisk User Guide 2 • Read file segments into SIGNAL for precision display and measurement NIDisk does not require SIGNAL in order to operate - it

Pagina 36

NIDisk User Guide 3 Install NI-DAQmx System Driver and Configure I/O Card NIDisk 3.0 requires NI-DAQmx 8.0 or later. Instructions for downloading and

Comentarios a estos manuales